Critical Technical Advantages
-
Media-Independent Accuracy: Unlike ultrasonic or pressure-based sensors, the FMP50 is not affected by changes in density, temperature, or conductivity. It provides reliable data even if the liquid is replaced by a different medium or if heavy vapors and gas layers are present above the liquid.
-
Multi-Echo Tracking: The FMP50 utilizes advanced Multi-Echo Tracking evaluation. This software innovation ensures the device can distinguish between the true level signal and interference echoes from tank internal structures or buildup on the probe, leading to the highest reliability in the basic segment.
-
HistoROM Data Management: The integrated HistoROM concept stores all device parameters and event logs. This allows for fast and easy commissioning, simplified maintenance, and rapid diagnostics. If a transmitter electronics module needs replacement, the settings are automatically restored from the HistoROM.
-
SIL3 Ready Design: Both hardware and software are developed according to IEC 61508, making the device suitable for use in safety-instrumented systems up to SIL3 (in homogeneous redundancy). It also features the world’s easiest proof test for SIL and WHG (overfill prevention), which can be performed without removing the sensor or changing the level.
-
Heartbeat Technology: This suite enables continuous self-monitoring and traceable verification of the device’s functionality. It identifies process-related issues, such as probe coating, before they lead to a measurement failure, ensuring safe plant operation throughout the entire life cycle.
-
Flexible Probe Versions: Depending on the tank height and headspace, the FMP50 is available with a rigid rod probe (up to 4m) for smaller vessels or a flexible rope probe (up to 12m) for deeper storage tanks.
Detailed Technical Performance Matrix
| Specification | Technical Details and Ranges |
| Measuring Principle | Guided Wave Radar (Time-of-Flight) |
| Measuring Range | Rod: up to 4 m (13 ft); Rope: up to 12 m (39 ft) |
| Measurement Accuracy | ±2 mm (0.08″) |
| Process Temperature | -20 to +80 °C (-4 to +176 °F) |
| Process Pressure | -1 to +6 bar (-14.5 to +87 psi) |
| Process Connections | Threads (G¾, NPT¾) or adapter flanges |
| Output / Communication | 4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Safety Certifications | SIL2/3, WHG (Overfill prevention), ATEX, IECEx, FM, CSA |
Primary Applications
-
Water and Wastewater Utilities: Monitoring levels in storage tanks, flocculant containers, and neutralized water basins.
-
Basic Chemical Storage: Level measurement in tanks for non-aggressive acids, alkalis, or cleaning agents (CIP).
-
Food and Beverage: Utility processes such as water storage or basic ingredient tanks where high temperatures are not present.
-
Service Tanks: Managing levels of oils, lubricants, or coolants in industrial machinery and power plants.
-
Paste and Slurry Monitoring: Reliable level tracking in thick or viscous liquids where non-contact radar might struggle with signal absorption.