Home / News / Micropilot FMR62B Radar Level Transmitter | 80 GHz Technical Guide & Selection

Micropilot FMR62B Radar Level Transmitter | 80 GHz Technical Guide & Selection

Micropilot FMR62B

80 GHz Radar Level Transmitter | ±1 mm Accuracy | –196 to +450°C | SIL 2/3 Certified

Micropilot FMR62B 80GHz radar level transmitter top view with blue housing

Technical Overview

The Micropilot FMR62B represents the next generation of 80 GHz non-contact radar measurement technology from Endress+Hauser. Designed for demanding liquid applications in process industries, the Micropilot FMR62B radar level transmitter delivers exceptional performance in high-temperature, high-pressure, and corrosive environments where traditional measurement technologies fail.

As a trusted supplier of Endress+Hauser instruments, YUNRUI provides genuine FMR62B radar level transmitter units with full technical support and fast global delivery.

🔬 80 GHz Technology Breakthrough

The Micropilot FMR62B radar level transmitter operates at 80 GHz W-band frequency, delivering significant advantages over conventional 26 GHz radar transmitters:

Feature FMR62B (80 GHz) Conventional (26 GHz)
Beam Angle 8° typical
Minimum Measuring Distance 0.3 m (12 in) 1 m+ (39 in)
Resolution 1 mm (0.04 in) 3 mm+ (0.12 in)
Interference Suppression Excellent (narrow beam) Moderate
Nozzle Compatibility DN50 / 2″ and larger DN80 / 3″ and larger

The narrow 3° beam angle eliminates interference from tank walls, internal structures, and agitators, making the FMR62B radar level transmitter ideal for complex tank geometries.

📊 Technical Specifications

Performance Parameters

Parameter Specification
Measuring Principle Free-space radar (80 GHz FMCW)
Maximum Range 80 m (262.5 ft)
Accuracy ±1 mm (0.04 in)
Repeatability ±0.5 mm (0.02 in)
Process Temperature –196 to +450 °C (–321 to +842 °F)
Process Pressure –1 to +160 bar (–14.5 to +2,321 psi)
Peak Output Power <1.5 mW
Average Output Power <70 μW

Communication and Output

Output Specification
Primary Output 4–20 mA HART (2-wire)
Optional Output 2 4–20 mA (assignable)
Switch Output Open collector (optional)
Wireless Bluetooth® for configuration
Supply Voltage 10.5–35 V DC
Alarm Signal 3.6–22 mA (NAMUR NE 43)

Micropilot FMR62B 80GHz radar level transmitter front view with display and flange

🔧 Antenna Options and Materials

Selecting the correct antenna is critical for FMR62B radar level transmitter performance in specific applications:

Antenna Type Material Size Best Application
PTFE Drip-off PTFE 50 mm (2 in) Condensing vapors, build-up prone media
PTFE Cladded (Flush) PTFE encapsulated 50 mm (2 in) Corrosive liquids, hygienic requirements
PTFE Cladded (Flush) PTFE encapsulated 80 mm (3 in) Maximum signal strength, large nozzles
Horn Antenna 316L stainless steel 65 mm (2.6 in) Standard applications, cost-effective

Housing Options

Housing Type Material Application
Single Compartment Plastic Standard, cost-effective
Single Compartment Aluminum General industrial
Single Compartment (Hygienic) 316L stainless steel Food, pharmaceutical
Dual Compartment Aluminum/Stainless steel Separation of electronics and terminals
Dual Compartment (L-Form) Aluminum/Stainless steel Flexible display positioning

💓 Heartbeat Technology™

The Micropilot FMR62B features Endress+Hauser’s proprietary Heartbeat Technology for continuous self-monitoring and diagnostics of the FMR62B radar level transmitter:

Heartbeat Verification

  • Self-Verification: Automated device status check without process interruption
  • Build-up Detection: Early warning for antenna contamination (3-week advance notice)
  • Build-up Index: Quantified measurement of antenna fouling

Heartbeat Monitoring

  • Foam Detection: Automatic identification of foam layers on liquid surface
  • Foam Index: Quantified foam level assessment
  • Loop Diagnostics: Continuous monitoring of 4–20 mA loop integrity

Heartbeat Diagnostics

  • Process Connection Leak Detection: Pressure transient analysis
  • Electronics Health Score: Predictive assessment of remaining device lifetime

🛡️ Certifications and Standards

Certification Standard Application
SIL 2 IEC 61508 Single device (standard)
SIL 3 IEC 61508 Homogeneous redundancy architecture
Explosion Protection ATEX, IECEx Hazardous area installation
Overfill Protection WHG German water resources act compliance
Marine Ship classification Offshore and marine applications
Factory Calibration 5-point or 10-point Traceable measurement accuracy

🏭 Applications and Industries

🧪 Chemical Industry

  • Corrosive Liquids: PTFE antenna handles acids, alkalis, and aggressive chemicals
  • Reaction Vessels: 160 bar pressure rating for high-pressure processes
  • Storage Tanks: 80 m range for large chemical storage facilities

🛢️ Oil and Gas

  • Crude Oil Tanks: Reliable measurement despite varying dielectric constants
  • LNG Storage: –196 °C operation for cryogenic applications
  • Process Separators: Foam detection for interface measurement

🍔 Food and Pharmaceutical

  • Hygienic Vessels: 316L housing and PTFE antenna meet sanitary requirements
  • CIP/SIP Processes: Temperature resistant for cleaning cycles
  • Storage Silos: Precise inventory management

⚡ Power Generation

  • Boiler Feedwater: High-temperature condensate measurement
  • Cooling Water: Reliable level in cooling tower basins

Micropilot FMR62B 80GHz radar level transmitter side view showing flange and antenna details

🔧 Installation Guidelines

Mounting Location

  • Storage Vessels: Center mounting for calm liquid surfaces
  • Buffer Vessels: Offset from inlet to avoid surface turbulence
  • Agitated Vessels: Avoid baffles and agitator blades in beam path

Nozzle Requirements

Antenna Size Minimum Nozzle Diameter Maximum Nozzle Length
50 mm (2 in) DN50 / 2″ See manual (D-dependent)
65 mm (2.6 in) DN65 / 2.5″ See manual (D-dependent)
80 mm (3 in) DN80 / 3″ See manual (D-dependent)

Important: Excessive nozzle length causes signal degradation. Consult factory for nozzles exceeding standard lengths.

Stilling Well / Bypass Applications

  • 80 mm flush-mount antenna compatible with 80 mm (3 in) stilling wells
  • Maximum measuring range in pipe: 20 m (65.6 ft)
  • Accuracy reduced compared to free-space measurement

📱 Commissioning and Operation

Configuration Methods

  • Bluetooth® Wireless: Secure wireless configuration via SmartBlue app
  • Local Display: Intuitive menu-guided setup
  • HART Communicator: Standard HART protocol support
  • PC Software: FieldCare, DeviceCare, Field Xpert SMT70

Guided Commissioning

The FMR62B features wizard-based commissioning that guides users through:

  1. Tank geometry configuration
  2. Medium property selection (dielectric constant)
  3. Interference echo mapping
  4. Signal optimization
  5. Output configuration

Operation and Monitoring

  • Display: Measured value, bar graph, and diagnostic icons
  • Status Signals: NAMUR NE 107 (Failure, Function Check, Out of Specification, Maintenance Required)
  • Remote Access: HART, Bluetooth, or WirelessHART

⚡ Competitive Advantages

Parameter FMR62B Typical Competitor
Frequency 80 GHz 26 GHz
Beam Angle 8–10°
Accuracy ±1 mm ±3 mm
Temperature Range –196 to +450 °C –40 to +200 °C
Pressure Range –1 to +160 bar –1 to +40 bar
SIL Certification SIL 2/3 Often missing
Heartbeat Technology Integrated Not available

📚 Related Reading

Explore more Endress+Hauser measurement solutions:

📞 Request a Quote

For pricing, availability, and technical assistance with the Micropilot FMR62B radar level transmitter, contact our application engineers:

Email: sales@yunrui-controls.com
WhatsApp: 18710784030

We supply genuine Endress+Hauser instruments with full factory support, fast global delivery, and competitive pricing for volume orders.

Get A Quote

Scroll to Top