Micropilot FMR62B
80 GHz Radar Level Transmitter | ±1 mm Accuracy | –196 to +450°C | SIL 2/3 Certified

Technical Overview
The Micropilot FMR62B represents the next generation of 80 GHz non-contact radar measurement technology from Endress+Hauser. Designed for demanding liquid applications in process industries, the Micropilot FMR62B radar level transmitter delivers exceptional performance in high-temperature, high-pressure, and corrosive environments where traditional measurement technologies fail.
As a trusted supplier of Endress+Hauser instruments, YUNRUI provides genuine FMR62B radar level transmitter units with full technical support and fast global delivery.
🔬 80 GHz Technology Breakthrough
The Micropilot FMR62B radar level transmitter operates at 80 GHz W-band frequency, delivering significant advantages over conventional 26 GHz radar transmitters:
| Feature | FMR62B (80 GHz) | Conventional (26 GHz) |
|---|---|---|
| Beam Angle | 3° | 8° typical |
| Minimum Measuring Distance | 0.3 m (12 in) | 1 m+ (39 in) |
| Resolution | 1 mm (0.04 in) | 3 mm+ (0.12 in) |
| Interference Suppression | Excellent (narrow beam) | Moderate |
| Nozzle Compatibility | DN50 / 2″ and larger | DN80 / 3″ and larger |
The narrow 3° beam angle eliminates interference from tank walls, internal structures, and agitators, making the FMR62B radar level transmitter ideal for complex tank geometries.
📊 Technical Specifications
Performance Parameters
| Parameter | Specification |
|---|---|
| Measuring Principle | Free-space radar (80 GHz FMCW) |
| Maximum Range | 80 m (262.5 ft) |
| Accuracy | ±1 mm (0.04 in) |
| Repeatability | ±0.5 mm (0.02 in) |
| Process Temperature | –196 to +450 °C (–321 to +842 °F) |
| Process Pressure | –1 to +160 bar (–14.5 to +2,321 psi) |
| Peak Output Power | <1.5 mW |
| Average Output Power | <70 μW |
Communication and Output
| Output | Specification |
|---|---|
| Primary Output | 4–20 mA HART (2-wire) |
| Optional Output 2 | 4–20 mA (assignable) |
| Switch Output | Open collector (optional) |
| Wireless | Bluetooth® for configuration |
| Supply Voltage | 10.5–35 V DC |
| Alarm Signal | 3.6–22 mA (NAMUR NE 43) |

🔧 Antenna Options and Materials
Selecting the correct antenna is critical for FMR62B radar level transmitter performance in specific applications:
| Antenna Type | Material | Size | Best Application |
|---|---|---|---|
| PTFE Drip-off | PTFE | 50 mm (2 in) | Condensing vapors, build-up prone media |
| PTFE Cladded (Flush) | PTFE encapsulated | 50 mm (2 in) | Corrosive liquids, hygienic requirements |
| PTFE Cladded (Flush) | PTFE encapsulated | 80 mm (3 in) | Maximum signal strength, large nozzles |
| Horn Antenna | 316L stainless steel | 65 mm (2.6 in) | Standard applications, cost-effective |
Housing Options
| Housing Type | Material | Application |
|---|---|---|
| Single Compartment | Plastic | Standard, cost-effective |
| Single Compartment | Aluminum | General industrial |
| Single Compartment (Hygienic) | 316L stainless steel | Food, pharmaceutical |
| Dual Compartment | Aluminum/Stainless steel | Separation of electronics and terminals |
| Dual Compartment (L-Form) | Aluminum/Stainless steel | Flexible display positioning |
💓 Heartbeat Technology™
The Micropilot FMR62B features Endress+Hauser’s proprietary Heartbeat Technology for continuous self-monitoring and diagnostics of the FMR62B radar level transmitter:
Heartbeat Verification
- Self-Verification: Automated device status check without process interruption
- Build-up Detection: Early warning for antenna contamination (3-week advance notice)
- Build-up Index: Quantified measurement of antenna fouling
Heartbeat Monitoring
- Foam Detection: Automatic identification of foam layers on liquid surface
- Foam Index: Quantified foam level assessment
- Loop Diagnostics: Continuous monitoring of 4–20 mA loop integrity
Heartbeat Diagnostics
- Process Connection Leak Detection: Pressure transient analysis
- Electronics Health Score: Predictive assessment of remaining device lifetime
🛡️ Certifications and Standards
| Certification | Standard | Application |
|---|---|---|
| SIL 2 | IEC 61508 | Single device (standard) |
| SIL 3 | IEC 61508 | Homogeneous redundancy architecture |
| Explosion Protection | ATEX, IECEx | Hazardous area installation |
| Overfill Protection | WHG | German water resources act compliance |
| Marine | Ship classification | Offshore and marine applications |
| Factory Calibration | 5-point or 10-point | Traceable measurement accuracy |
🏭 Applications and Industries
🧪 Chemical Industry
- Corrosive Liquids: PTFE antenna handles acids, alkalis, and aggressive chemicals
- Reaction Vessels: 160 bar pressure rating for high-pressure processes
- Storage Tanks: 80 m range for large chemical storage facilities
🛢️ Oil and Gas
- Crude Oil Tanks: Reliable measurement despite varying dielectric constants
- LNG Storage: –196 °C operation for cryogenic applications
- Process Separators: Foam detection for interface measurement
🍔 Food and Pharmaceutical
- Hygienic Vessels: 316L housing and PTFE antenna meet sanitary requirements
- CIP/SIP Processes: Temperature resistant for cleaning cycles
- Storage Silos: Precise inventory management
⚡ Power Generation
- Boiler Feedwater: High-temperature condensate measurement
- Cooling Water: Reliable level in cooling tower basins

🔧 Installation Guidelines
Mounting Location
- Storage Vessels: Center mounting for calm liquid surfaces
- Buffer Vessels: Offset from inlet to avoid surface turbulence
- Agitated Vessels: Avoid baffles and agitator blades in beam path
Nozzle Requirements
| Antenna Size | Minimum Nozzle Diameter | Maximum Nozzle Length |
|---|---|---|
| 50 mm (2 in) | DN50 / 2″ | See manual (D-dependent) |
| 65 mm (2.6 in) | DN65 / 2.5″ | See manual (D-dependent) |
| 80 mm (3 in) | DN80 / 3″ | See manual (D-dependent) |
Important: Excessive nozzle length causes signal degradation. Consult factory for nozzles exceeding standard lengths.
Stilling Well / Bypass Applications
- 80 mm flush-mount antenna compatible with 80 mm (3 in) stilling wells
- Maximum measuring range in pipe: 20 m (65.6 ft)
- Accuracy reduced compared to free-space measurement
📱 Commissioning and Operation
Configuration Methods
- Bluetooth® Wireless: Secure wireless configuration via SmartBlue app
- Local Display: Intuitive menu-guided setup
- HART Communicator: Standard HART protocol support
- PC Software: FieldCare, DeviceCare, Field Xpert SMT70
Guided Commissioning
The FMR62B features wizard-based commissioning that guides users through:
- Tank geometry configuration
- Medium property selection (dielectric constant)
- Interference echo mapping
- Signal optimization
- Output configuration
Operation and Monitoring
- Display: Measured value, bar graph, and diagnostic icons
- Status Signals: NAMUR NE 107 (Failure, Function Check, Out of Specification, Maintenance Required)
- Remote Access: HART, Bluetooth, or WirelessHART
⚡ Competitive Advantages
| Parameter | FMR62B | Typical Competitor |
|---|---|---|
| Frequency | 80 GHz | 26 GHz |
| Beam Angle | 3° | 8–10° |
| Accuracy | ±1 mm | ±3 mm |
| Temperature Range | –196 to +450 °C | –40 to +200 °C |
| Pressure Range | –1 to +160 bar | –1 to +40 bar |
| SIL Certification | SIL 2/3 | Often missing |
| Heartbeat Technology | Integrated | Not available |
📚 Related Reading
Explore more Endress+Hauser measurement solutions:
- Micropilot FMR62B Radar Level Transmitter — Product specifications and availability
- Micropilot FMR67 Radar Level Transmitter — 80 GHz radar for demanding applications
- Cerabar PMP51B Pressure Transmitter — Digital pressure measurement with Bluetooth
- Endress+Hauser Brand Page — Complete instrument portfolio
- Radar Level Transmitter: High vs Low Frequency — Technical comparison guide
📞 Request a Quote
For pricing, availability, and technical assistance with the Micropilot FMR62B radar level transmitter, contact our application engineers:
Email: sales@yunrui-controls.com
WhatsApp: 18710784030
We supply genuine Endress+Hauser instruments with full factory support, fast global delivery, and competitive pricing for volume orders.