Critical Technical Advantages
-
High-Pressure Barstock Design: Specifically built to withstand immense process pressures up to 500 bar. The barstock thermowell provides a massive mechanical barrier, making it suitable for high-velocity steam or high-pressure hydrocarbon flows.
-
Dual Seal Technology: This features a secondary process seal that acts as a backup barrier. In the event of a primary thermowell breach, the Dual Seal prevents process media from escaping into the terminal head and provides a failure indication, allowing for proactive maintenance and enhanced plant safety.
-
Simplified Maintenance (iTHERM QuickNeck): The TM152 features the divisible QuickNeck, which allows the upper part of the thermometer to be removed for recalibration without tools. This can be done without interrupting the process or disconnecting wiring, significantly reducing maintenance costs and downtime.
-
Extreme Vibration Resistance (iTHERM StrongSens): For applications near high-vibration equipment like turbines or compressors, the StrongSens insert offers resistance greater than 60g, ensuring long-term measurement stability and preventing mechanical failure.
-
Industry-Leading Response (iTHERM QuickSens): With a response time of just 1.5 seconds, the QuickSens technology ensures that even the smallest temperature fluctuations are detected almost instantly, providing superior control in sensitive thermal processes.
-
Global Digital Connectivity: The integrated iTEMP transmitter supports HART, PROFIBUS PA, and FOUNDATION Fieldbus. Optional Bluetooth connectivity enables wireless commissioning and diagnostics via mobile devices, improving safety in hazardous or hard-to-reach locations.
Technical Performance Matrix
| Feature | Details |
| Measuring Range | –200 to +1,100 °C (–328 to +2,012 °F) |
| Max. Pressure | 500 bar (7,252 psi) |
| Sensor Type | RTD (Pt100) or Thermocouple (TC) |
| Vibration Resistance | > 60g (with iTHERM StrongSens) |
| Response Time | 1.5 s (with iTHERM QuickSens) |
| Safety Features | Dual Seal technology (Second process barrier) |
| Communication | 4-20 mA, HART, PROFIBUS PA, FF, Bluetooth |
| Functional Safety | SIL (Functional Safety) |
Primary Applications
-
High-Pressure Oil & Gas: Critical temperature monitoring in high-pressure separators, wellheads, and offshore production facilities where imperial standards are used.
-
Power & Energy: Measuring high-pressure, high-velocity steam in power generation plants where vibration and safety barriers are essential.
-
Chemical Industry: Monitoring reactors containing toxic or flammable media that require secondary containment (Dual Seal) and SIL-rated safety loops.
-
High-Density Maintenance Loops: Measuring points that require frequent recalibration; the QuickNeck and replaceable sensor inserts allow for rapid service without process shutdown.
-