Critical Technical Advantages
-
Maximum Safety for Hazardous Zones: With FM and CSA XP Class I, Div. 1 approvals, the T14 is designed to contain any internal explosion, preventing the ignition of the surrounding flammable atmosphere. This makes it a standard for refineries and offshore platforms.
-
Superior Pressure and Corrosion Resistance: The barstock thermowell is machined from solid metal, allowing the T14 to handle extreme mechanical loads and high-pressure steam or chemical lines. The use of specialized materials ensures the device remains intact even when exposed to highly corrosive process media.
-
Enhanced Signal Reliability: By utilizing integrated iTEMP head transmitters, the T14 converts the Pt100 signal to a digital protocol (such as HART or Fieldbus) directly at the point of measurement. This provides a 2 kV galvanic isolation and protects the data from electromagnetic interference.
-
Long-Term Calibration Stability: The included transmitters are rated for a stability of $\le$0.05% per year. This high level of repeatability reduces the need for frequent field calibrations, lowering maintenance costs and ensuring consistent process quality.
-
Simplified Field Service: The “straight out of the box” design means the sensor is pre-assembled with the thermowell and transmitter. This modularity allows for easy removal and installation without needing to specify and match individual components from multiple vendors.
-
Comprehensive Model Structure: The T14 utilizes a simplified ordering code that includes all necessary components. This reduces the risk of specification errors during the procurement phase for large-scale projects.
Technical Performance Matrix
| Feature | Details |
| Sensor Type | Pt100 RTD (Insulated element and sheath) |
| Approval | FM/CSA XP Class I, Div. 1 (Explosion Proof) |
| Thermowell Construction | Machined Barstock (Heavy-duty) |
| Galvanic Isolation | 2 kV (on most transmitter models) |
| Annual Stability | $\le$0.05% (iTEMP Transmitters) |
| Communication | 4-20mA, HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Industry Standard | US Style (North American specifications) |
Primary Applications
-
Offshore Oil and Gas: Reliable temperature monitoring in salt-laden, high-pressure environments on drilling and production platforms.
-
Chemical Reactors: Tracking exothermic reactions where both high pressure and explosive vapors are present.
-
Petrochemical Refineries: Monitoring critical distillation and cracking processes that require FM/CSA certified instrumentation.
-
Power Generation: Measuring high-pressure steam and feedwater temperatures in utility plants.
-
Heavy Industrial Processing: Any application requiring a robust “point solution” that can withstand physical abuse and corrosive chemical exposure.