{"id":8293,"date":"2026-05-28T18:14:48","date_gmt":"2026-05-28T18:14:48","guid":{"rendered":"https:\/\/www.yunrui-controls.com\/?p=8293"},"modified":"2026-05-28T18:15:16","modified_gmt":"2026-05-28T18:15:16","slug":"overpressure-protection-relief-valve","status":"publish","type":"post","link":"https:\/\/www.yunrui-controls.com\/ko\/overpressure-protection-relief-valve\/","title":{"rendered":"\uacfc\uc555 \ubcf4\ud638: \uc548\uc804 \ubc38\ube0c \uc791\ub3d9 \uc6d0\ub9ac \ubc0f Fisher \uc2dc\ub9ac\uc988 \uac00\uc774\ub4dc"},"content":{"rendered":"<div style=\"max-width: 900px; margin: 0 auto; font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif; line-height: 1.7; color: #2c3e50;\">\n<p><!-- Hero Section --><\/p>\n<div style=\"background: linear-gradient(135deg, #c0392b 0%, #e74c3c 100%); padding: 40px; border-radius: 12px; margin-bottom: 30px; text-align: center;\">\n<h1 style=\"color: white; margin: 0 0 15px 0; font-size: 2.2em; font-weight: bold;\">Overpressure Protection: Relief Valve Working Principles<\/h1>\n<p style=\"color: rgba(255,255,255,0.95); font-size: 1.2em; margin: 0; font-weight: 300;\">Essential Safety Systems for Gas Pipeline Pressure Control<\/p>\n<\/div>\n<p><!-- Warning Box --><\/p>\n<div style=\"background: #fff3cd; border-left: 5px solid #ffc107; padding: 25px; margin: 30px 0; border-radius: 0 8px 8px 0;\">\n<h3 style=\"margin: 0 0 10px 0; color: #856404;\">\u26a0\ufe0f Critical Safety Note<\/h3>\n<p style=\"margin: 0; color: #856404;\"><strong>Overpressure protection<\/strong> is a fundamental consideration in all pipeline system designs. Its purpose is to maintain the downstream pressure of the regulator at a safe maximum value. Without proper protection, system failure can result in catastrophic consequences.<\/p>\n<\/div>\n<p><!-- Introduction --><\/p>\n<h2 style=\"color: #2c3e50; border-bottom: 3px solid #e74c3c; padding-bottom: 10px; margin-top: 40px;\">Understanding Overpressure Protection<\/h2>\n<p>A high-pressure transmission and distribution system delivers natural gas through a regulator to a low-pressure system serving individual users. The regulator, piping, and gas handling equipment are protected against overpressure conditions by <strong style=\"color: #c0392b;\">relief valves<\/strong>.<\/p>\n<p>The relief valve setpoint is adjusted to a pressure level determined by the <strong>minimum maximum rated pressure value<\/strong> of the low-pressure system components.<\/p>\n<p><!-- How It Works --><\/p>\n<h2 style=\"color: #2c3e50; border-bottom: 3px solid #e74c3c; padding-bottom: 10px; margin-top: 40px;\">How Overpressure Occurs<\/h2>\n<p>Overpressure occurs when system pressure exceeds the setpoint of the equipment controlling it. This indicates an error in the system (typically at the upstream regulator). If this pressure is not limited, it can lead to complete system failure.<\/p>\n<div style=\"background: #e8f4f8; padding: 25px; border-radius: 8px; margin: 25px 0;\">\n<h4 style=\"margin: 0 0 15px 0; color: #c0392b;\">To implement overpressure protection:<\/h4>\n<ol style=\"margin: 0; padding-left: 20px;\">\n<li style=\"margin-bottom: 10px;\">Identify the weakest part of the system<\/li>\n<li style=\"margin-bottom: 10px;\">Limit excessive pressure below the maximum rated pressure of that component<\/li>\n<\/ol>\n<\/div>\n<p><!-- Maximum Pressure Considerations --><\/p>\n<h2 style=\"color: #2c3e50; border-bottom: 3px solid #e74c3c; padding-bottom: 10px; margin-top: 40px;\">Maximum Pressure Considerations<\/h2>\n<p>Check the following components to determine the weakest part of the pressure-containing system:<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(250px, 1fr)); gap: 20px; margin: 25px 0;\">\n<div style=\"background: white; border-radius: 10px; padding: 25px; box-shadow: 0 4px 6px rgba(0,0,0,0.07); border-top: 4px solid #e74c3c;\">\n<h3 style=\"margin: 0 0 15px 0; color: #e74c3c; font-size: 1.2em;\">\ud83d\udd27 Downstream Equipment<\/h3>\n<p style=\"margin: 0; color: #555;\">The downstream component with the smallest maximum rated pressure (appliances, burners, boilers, etc.) determines the highest pressure value for all downstream equipment.<\/p>\n<\/div>\n<div style=\"background: white; border-radius: 10px; padding: 25px; box-shadow: 0 4px 6px rgba(0,0,0,0.07); border-top: 4px solid #3498db;\">\n<h3 style=\"margin: 0 0 15px 0; color: #3498db; font-size: 1.2em;\">\u2699\ufe0f Main Regulator<\/h3>\n<p style=\"margin: 0; color: #555;\">Regulators have different pressure ratings: inlet pressure, outlet pressure, and internal pressure. The minimum of these determines the maximum allowable pressure.<\/p>\n<\/div>\n<div style=\"background: white; border-radius: 10px; padding: 25px; box-shadow: 0 4px 6px rgba(0,0,0,0.07); border-top: 4px solid #27ae60;\">\n<h3 style=\"margin: 0 0 15px 0; color: #27ae60; font-size: 1.2em;\">\ud83d\udd04 Piping<\/h3>\n<p style=\"margin: 0; color: #555;\">Piping is limited by its pressure-containing capacity. Besides physical limitations, practical applications must comply with one or more applicable rated pressure codes or regulations.<\/p>\n<\/div>\n<\/div>\n<div style=\"background: #e8f8f5; padding: 20px; border-radius: 8px; margin: 25px 0; border-left: 4px solid #27ae60;\">\n<p style=\"margin: 0;\"><strong>Key Principle:<\/strong> \uadf8\ub9cc\ud07c <strong>lowest value<\/strong> among these three maximum rated pressures becomes the <strong>maximum allowable pressure<\/strong> for the entire system.<\/p>\n<\/div>\n<p><!-- Relief Valve Function --><\/p>\n<h2 style=\"color: #2c3e50; border-bottom: 3px solid #e74c3c; padding-bottom: 10px; margin-top: 40px;\">Relief Valve Function<\/h2>\n<p>Relief is accomplished through a device that vents fluid to another low-pressure system (usually the atmosphere) to maintain the downstream pressure of the regulator at a safe maximum value.<\/p>\n<div style=\"background: #fff3cd; border-left: 5px solid #ffc107; padding: 20px; margin: 25px 0; border-radius: 0 8px 8px 0;\">\n<h4 style=\"margin: 0 0 10px 0; color: #856404;\">\u26a0\ufe0f Important Safety Requirement<\/h4>\n<p style=\"margin: 0; color: #856404;\">Relief valve discharge must be directed to a <strong>safe location<\/strong>. Proper venting is essential for safe operation.<\/p>\n<\/div>\n<p>Relief valves are considered the <strong style=\"color: #c0392b;\">most reliable overpressure protection method<\/strong> available and come in many different forms.<\/p>\n<p><!-- Fisher Relief Valves --><\/p>\n<div style=\"background: linear-gradient(135deg, #667eea 0%, #764ba2 100%); padding: 30px; border-radius: 12px; color: white; margin: 30px 0;\">\n<h3 style=\"margin: 0 0 15px 0; font-size: 1.3em;\"><a href=\"https:\/\/www.yunrui-controls.com\/ko\/brands\/fisher\/regulators-relief-valves\/\"><span style=\"color: #ffffff;\">Fisher Relief Valve Series<\/span><\/a><\/h3>\n<p style=\"margin: 0 0 15px 0; opacity: 0.95;\"><strong>Note:<\/strong> Fisher relief valves are <strong>NOT<\/strong> ASME safety valves. They are designed specifically for gas pressure regulation applications.<\/p>\n<p style=\"margin: 0;\">YUNRUI provides complete Fisher relief valve solutions for natural gas systems.<\/p>\n<\/div>\n<p><!-- Common Fisher Series --><\/p>\n<h2 style=\"color: #2c3e50; border-bottom: 3px solid #e74c3c; padding-bottom: 10px; margin-top: 40px;\">Common <a href=\"https:\/\/www.yunrui-controls.com\/ko\/brands\/fisher\/regulators-relief-valves\/\">Fisher Relief Valve Series<\/a><\/h2>\n<table style=\"width: 100%; border-collapse: collapse; margin: 25px 0; font-size: 14px; background-color: white; box-shadow: 0 2px 8px rgba(0,0,0,0.1);\">\n<thead>\n<tr style=\"background: linear-gradient(135deg, #c0392b 0%, #e74c3c 100%);\">\n<th style=\"padding: 15px; text-align: left; color: white; font-weight: 600;\">\uc2dc\ub9ac\uc988<\/th>\n<th style=\"padding: 15px; text-align: left; color: white; font-weight: 600;\">\uc720\ud615<\/th>\n<th style=\"padding: 15px; text-align: left; color: white; font-weight: 600;\">\uc751\uc6a9 \ud504\ub85c\uadf8\ub7a8<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background-color: #f8f9fa;\">\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0; font-weight: 600;\"><a href=\"https:\/\/www.yunrui-controls.com\/ko\/products\/fisher-h200-series\/\">Fisher H200 Series<\/a><\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">\ub9b4\ub9ac\ud504 \ubc38\ube0c<\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">Low-pressure gas systems<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0; font-weight: 600;\">Fisher H800 Series<\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">\ub9b4\ub9ac\ud504 \ubc38\ube0c<\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">Medium-pressure applications<\/td>\n<\/tr>\n<tr style=\"background-color: #f8f9fa;\">\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0; font-weight: 600;\"><a href=\"https:\/\/www.yunrui-controls.com\/ko\/products\/fisher-289-series\/\">Fisher 289 Series<\/a><\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">\ub9b4\ub9ac\ud504 \ubc38\ube0c<\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">Commercial\/industrial systems<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0; font-weight: 600;\"><a href=\"https:\/\/www.yunrui-controls.com\/ko\/products\/fisher-627-series\/\">Fisher 627 Series<\/a><\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">Relief Valve\/Backpressure<\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">Direct-operated regulators<\/td>\n<\/tr>\n<tr style=\"background-color: #f8f9fa;\">\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0; font-weight: 600;\"><a href=\"https:\/\/www.yunrui-controls.com\/ko\/products\/fisher-type-630\/\">Fisher 630 Series<\/a><\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">\ub9b4\ub9ac\ud504 \ubc38\ube0c<\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">High-capacity relief<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0; font-weight: 600;\"><a href=\"https:\/\/www.yunrui-controls.com\/ko\/products\/fisher-mr98-series\/\">\ud53c\uc154 MR98 \uc2dc\ub9ac\uc988<\/a><\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">\ub9b4\ub9ac\ud504 \ubc38\ube0c<\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">Compact design applications<\/td>\n<\/tr>\n<tr style=\"background-color: #f8f9fa;\">\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0; font-weight: 600;\"><a href=\"https:\/\/www.yunrui-controls.com\/ko\/products\/fisher-ezr-series\/\">Fisher EZR Series<\/a><\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">\ub9b4\ub9ac\ud504 \ubc38\ube0c<\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">High-pressure transmission<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0; font-weight: 600;\"><a href=\"https:\/\/www.yunrui-controls.com\/ko\/products\/fisher-type-63eg-98hm\/\">Fisher 63EG Series<\/a><\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">\ub9b4\ub9ac\ud504 \ubc38\ube0c<\/td>\n<td style=\"padding: 15px; border-bottom: 1px solid #e0e0e0;\">Pilot-operated systems<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!-- Selection Guide --><\/p>\n<h2 style=\"color: #2c3e50; border-bottom: 3px solid #e74c3c; padding-bottom: 10px; margin-top: 40px;\">Selection Guidelines<\/h2>\n<div style=\"display: flex; gap: 20px; margin: 25px 0; flex-wrap: wrap;\">\n<div style=\"flex: 1; min-width: 200px; background: #f8f9fa; padding: 25px; border-radius: 8px; border-left: 4px solid #e74c3c;\">\n<h3 style=\"margin: 0 0 15px 0; color: #e74c3c; font-size: 1.1em;\">\uc555\ub825 \ub4f1\uae09<\/h3>\n<p style=\"margin: 0; color: #555;\">Select valve based on system maximum allowable pressure and required relief capacity.<\/p>\n<\/div>\n<div style=\"flex: 1; min-width: 200px; background: #f8f9fa; padding: 25px; border-radius: 8px; border-left: 4px solid #3498db;\">\n<h3 style=\"margin: 0 0 15px 0; color: #3498db; font-size: 1.1em;\">\uc720\ub7c9 \uc6a9\ub7c9<\/h3>\n<p style=\"margin: 0; color: #555;\">Ensure adequate flow capacity for worst-case overpressure scenarios.<\/p>\n<\/div>\n<div style=\"flex: 1; min-width: 200px; background: #f8f9fa; padding: 25px; border-radius: 8px; border-left: 4px solid #27ae60;\">\n<h3 style=\"margin: 0 0 15px 0; color: #27ae60; font-size: 1.1em;\">Vent Location<\/h3>\n<p style=\"margin: 0; color: #555;\">Plan safe discharge routing away from ignition sources and occupied areas.<\/p>\n<\/div>\n<\/div>\n<p><!-- Conclusion --><\/p>\n<h2 style=\"color: #2c3e50; border-bottom: 3px solid #e74c3c; padding-bottom: 10px; margin-top: 40px;\">\uacb0\ub860<\/h2>\n<p>Proper overpressure protection is essential for safe gas system operation. Relief valves provide the most reliable protection by venting excess pressure to a safe location before system components are damaged.<\/p>\n<p>When selecting relief valves, always consider the <strong>weakest component<\/strong> in your system and ensure the relief valve setpoint is below its maximum rated pressure. <a style=\"color: #3498db; text-decoration: none; font-weight: 600;\" href=\"https:\/\/www.yunrui-controls.com\/ko\/brands\/fisher\/\">Fisher relief valves<\/a> offer proven performance across a wide range of pressure ratings and applications.<\/p>\n<div style=\"background: linear-gradient(135deg, #c0392b 0%, #e74c3c 100%); padding: 30px; border-radius: 12px; color: white; margin: 30px 0;\">\n<h3 style=\"margin: 0 0 15px 0;\">\ud575\uc2ec \uc694\uc57d<\/h3>\n<ul style=\"margin: 0; padding-left: 20px;\">\n<li style=\"margin-bottom: 8px;\">Overpressure protection is fundamental to pipeline safety<\/li>\n<li style=\"margin-bottom: 8px;\">Identify the weakest system component first<\/li>\n<li style=\"margin-bottom: 8px;\">Set relief valve below minimum rated pressure<\/li>\n<li style=\"margin-bottom: 8px;\">Ensure safe venting to atmosphere<\/li>\n<li style=\"margin-bottom: 8px;\">Fisher relief valves are NOT ASME safety valves<\/li>\n<\/ul>\n<\/div>\n<p><!-- Contact CTA --><\/p>\n<p><!-- Related Reading --><\/p>\n<h3 style=\"color: #2c3e50; margin-top: 40px;\">\ucd94\ucc9c \ub3c4\uc11c<\/h3>\n<ul style=\"padding-left: 20px;\">\n<li style=\"margin-bottom: 10px;\"><a href=\"https:\/\/www.yunrui-controls.com\/ko\/technical-manual-fisher-627-series-regulator\/\">Fisher 627 Pressure Reducing Regulator Technical Guide<\/a><\/li>\n<li style=\"margin-bottom: 10px;\"><a href=\"https:\/\/www.yunrui-controls.com\/ko\/fisher-ezr-regulator-operational-principles\/\">Fisher EZR Pressure Regulator: Features and Applications<\/a><\/li>\n<li style=\"margin-bottom: 10px;\"><a style=\"color: #3498db; text-decoration: none;\" href=\"https:\/\/www.yunrui-controls.com\/ko\/fisher-mr98-series-technical-specification\/\">Fisher MR98 Series Backpressure Regulator Overview<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Overpressure Protection: Relief Valve Working Principles Essential Safety Systems for Gas Pipeline Pressure Control \u26a0\ufe0f Critical Safety Note Overpressure protection is a fundamental consideration in all pipeline system designs. Its purpose is to maintain the downstream pressure of the regulator at a safe maximum value. Without proper protection, system failure can result in catastrophic consequences. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8002,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[384,1],"tags":[491,492,493,494,489,490,315,317],"class_list":["post-8293","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-blogs","tag-fisher-h200","tag-fisher-ezr","tag-gas-safety","tag-pressure-regulation","tag-relief-valve","tag-overpressure-protection","tag-fisher-627","tag-fisher-mr98"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.8 (Yoast SEO v26.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Overpressure Protection: Relief Valve Working Principles | YUNRUI<\/title>\n<meta name=\"description\" content=\"Learn about overpressure protection systems and Fisher relief valve series (H200, H800, 289, 627, 630, MR98, EZR, 63EG) for safe gas pipeline operation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.yunrui-controls.com\/ko\/overpressure-protection-relief-valve\/\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Overpressure Protection: Relief Valve Working Principles and Fisher Series Guide\" \/>\n<meta property=\"og:description\" content=\"Learn about overpressure protection systems and Fisher relief valve series (H200, H800, 289, 627, 630, MR98, EZR, 63EG) for safe gas pipeline operation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.yunrui-controls.com\/ko\/overpressure-protection-relief-valve\/\" \/>\n<meta property=\"og:site_name\" content=\"Fisher, E+H &amp; Rosemount Supplier from China | 100% Original | YUNRUI\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-28T18:14:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-28T18:15:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/ezr.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"750\" \/>\n\t<meta property=\"og:image:height\" content=\"797\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"sales@yunrui-controls.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\uae00\uc4f4\uc774\" \/>\n\t<meta name=\"twitter:data1\" content=\"sales@yunrui-controls.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04\" \/>\n\t<meta name=\"twitter:data2\" content=\"4\ubd84\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/\"},\"author\":{\"name\":\"sales@yunrui-controls.com\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/b9b385704b61e72ea9254fc3b56001af\"},\"headline\":\"Overpressure Protection: Relief Valve Working Principles and Fisher Series Guide\",\"datePublished\":\"2026-05-28T18:14:48+00:00\",\"dateModified\":\"2026-05-28T18:15:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/\"},\"wordCount\":627,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/ezr.jpeg\",\"keywords\":[\"Fisher H200\",\"Fisher EZR\",\"gas safety\",\"pressure regulation\",\"relief valve\",\"overpressure protection\",\"Fisher 627\",\"Fisher MR98\"],\"articleSection\":[\"News\",\"Blogs\"],\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/\",\"url\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/\",\"name\":\"Overpressure Protection: Relief Valve Working Principles | YUNRUI\",\"isPartOf\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/ezr.jpeg\",\"datePublished\":\"2026-05-28T18:14:48+00:00\",\"dateModified\":\"2026-05-28T18:15:16+00:00\",\"description\":\"Learn about overpressure protection systems and Fisher relief valve series (H200, H800, 289, 627, 630, MR98, EZR, 63EG) for safe gas pipeline operation.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#primaryimage\",\"url\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/ezr.jpeg\",\"contentUrl\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/ezr.jpeg\",\"width\":750,\"height\":797,\"caption\":\"Buy genuine Fisher EZR regulators - China supplier Yunrui\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.yunrui-controls.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Overpressure Protection: Relief Valve Working Principles and Fisher Series Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#website\",\"url\":\"https:\/\/www.yunrui-controls.com\/\",\"name\":\"Process Instrument & Valve Supplier from China | YUNRUI\",\"description\":\"YUNRUI is your trusted authorized distributor and stockist in China for original Fisher valves, E+H, and Rosemount instruments. Fast Middle East delivery. Get a quote!\",\"publisher\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/#organization\"},\"alternateName\":\"YRCONTROLS\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.yunrui-controls.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#organization\",\"name\":\"YUNRUI\",\"alternateName\":\"YUNRUI TRADING\",\"url\":\"https:\/\/www.yunrui-controls.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/03\/original-yunrui-logo-from-china-supplier-yunrui.png\",\"contentUrl\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/03\/original-yunrui-logo-from-china-supplier-yunrui.png\",\"width\":512,\"height\":512,\"caption\":\"YUNRUI\"},\"image\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/#\/schema\/logo\/image\/\"},\"telephone\":\"8618710784030\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/b9b385704b61e72ea9254fc3b56001af\",\"name\":\"sales@yunrui-controls.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/42e338d7dd3c1419e51612bcfd01acd3eca969f2e93b9e49b772042eceaf1030?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/42e338d7dd3c1419e51612bcfd01acd3eca969f2e93b9e49b772042eceaf1030?s=96&d=mm&r=g\",\"caption\":\"sales@yunrui-controls.com\"},\"sameAs\":[\"https:\/\/www.yunrui-controls.com\"],\"url\":\"https:\/\/www.yunrui-controls.com\/ko\/author\/gthgt-space-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\uacfc\uc555 \ubcf4\ud638: \uc548\uc804 \ubc38\ube0c \uc791\ub3d9 \uc6d0\ub9ac | \uc724\ub8e8\uc774","description":"Learn about overpressure protection systems and Fisher relief valve series (H200, H800, 289, 627, 630, MR98, EZR, 63EG) for safe gas pipeline operation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.yunrui-controls.com\/ko\/overpressure-protection-relief-valve\/","og_locale":"ko_KR","og_type":"article","og_title":"Overpressure Protection: Relief Valve Working Principles and Fisher Series Guide","og_description":"Learn about overpressure protection systems and Fisher relief valve series (H200, H800, 289, 627, 630, MR98, EZR, 63EG) for safe gas pipeline operation.","og_url":"https:\/\/www.yunrui-controls.com\/ko\/overpressure-protection-relief-valve\/","og_site_name":"Fisher, E+H &amp; Rosemount Supplier from China | 100% Original | YUNRUI","article_published_time":"2026-05-28T18:14:48+00:00","article_modified_time":"2026-05-28T18:15:16+00:00","og_image":[{"width":750,"height":797,"url":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/ezr.jpeg","type":"image\/jpeg"}],"author":"sales@yunrui-controls.com","twitter_card":"summary_large_image","twitter_misc":{"\uae00\uc4f4\uc774":"sales@yunrui-controls.com","\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04":"4\ubd84"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#article","isPartOf":{"@id":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/"},"author":{"name":"sales@yunrui-controls.com","@id":"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/b9b385704b61e72ea9254fc3b56001af"},"headline":"Overpressure Protection: Relief Valve Working Principles and Fisher Series Guide","datePublished":"2026-05-28T18:14:48+00:00","dateModified":"2026-05-28T18:15:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/"},"wordCount":627,"commentCount":0,"publisher":{"@id":"https:\/\/www.yunrui-controls.com\/#organization"},"image":{"@id":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#primaryimage"},"thumbnailUrl":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/ezr.jpeg","keywords":["Fisher H200","Fisher EZR","gas safety","pressure regulation","relief valve","overpressure protection","Fisher 627","Fisher MR98"],"articleSection":["News","Blogs"],"inLanguage":"ko-KR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/","url":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/","name":"\uacfc\uc555 \ubcf4\ud638: \uc548\uc804 \ubc38\ube0c \uc791\ub3d9 \uc6d0\ub9ac | \uc724\ub8e8\uc774","isPartOf":{"@id":"https:\/\/www.yunrui-controls.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#primaryimage"},"image":{"@id":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#primaryimage"},"thumbnailUrl":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/ezr.jpeg","datePublished":"2026-05-28T18:14:48+00:00","dateModified":"2026-05-28T18:15:16+00:00","description":"Learn about overpressure protection systems and Fisher relief valve series (H200, H800, 289, 627, 630, MR98, EZR, 63EG) for safe gas pipeline operation.","breadcrumb":{"@id":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#primaryimage","url":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/ezr.jpeg","contentUrl":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/ezr.jpeg","width":750,"height":797,"caption":"Buy genuine Fisher EZR regulators - China supplier Yunrui"},{"@type":"BreadcrumbList","@id":"https:\/\/www.yunrui-controls.com\/overpressure-protection-relief-valve\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.yunrui-controls.com\/"},{"@type":"ListItem","position":2,"name":"Overpressure Protection: Relief Valve Working Principles and Fisher Series Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.yunrui-controls.com\/#website","url":"https:\/\/www.yunrui-controls.com\/","name":"\uc911\uad6d \uacf5\uc815 \uacc4\uce21\uae30 \ubc0f \ubc38\ube0c \uacf5\uae09\uc5c5\uccb4 | YUNRUI","description":"YUNRUI\ub294 \uc911\uad6d\uc5d0\uc11c Fisher \uc815\ud488 \ubc38\ube0c, E+H \ubc0f Rosemount \uacc4\uce21\uae30\ub97c \uacf5\uae09\ud558\ub294 \uc2e0\ub8b0\ud560 \uc218 \uc788\ub294 \uacf5\uc2dd \uc720\ud1b5\uc5c5\uccb4\uc774\uc790 \uc7ac\uace0 \ubcf4\uc720\uc5c5\uccb4\uc785\ub2c8\ub2e4. \uc911\ub3d9 \uc9c0\uc5ed\uc73c\ub85c \ube60\ub978 \ubc30\uc1a1\uc774 \uac00\ub2a5\ud569\ub2c8\ub2e4. \uacac\uc801\uc744 \ubc1b\uc544\ubcf4\uc138\uc694!","publisher":{"@id":"https:\/\/www.yunrui-controls.com\/#organization"},"alternateName":"YRCONTROLS","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.yunrui-controls.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR"},{"@type":"Organization","@id":"https:\/\/www.yunrui-controls.com\/#organization","name":"\uc724\ub8e8\uc774","alternateName":"YUNRUI TRADING","url":"https:\/\/www.yunrui-controls.com\/","logo":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/www.yunrui-controls.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/03\/original-yunrui-logo-from-china-supplier-yunrui.png","contentUrl":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/03\/original-yunrui-logo-from-china-supplier-yunrui.png","width":512,"height":512,"caption":"YUNRUI"},"image":{"@id":"https:\/\/www.yunrui-controls.com\/#\/schema\/logo\/image\/"},"telephone":"8618710784030"},{"@type":"Person","@id":"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/b9b385704b61e72ea9254fc3b56001af","name":"sales@yunrui-controls.com","image":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/42e338d7dd3c1419e51612bcfd01acd3eca969f2e93b9e49b772042eceaf1030?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/42e338d7dd3c1419e51612bcfd01acd3eca969f2e93b9e49b772042eceaf1030?s=96&d=mm&r=g","caption":"sales@yunrui-controls.com"},"sameAs":["https:\/\/www.yunrui-controls.com"],"url":"https:\/\/www.yunrui-controls.com\/ko\/author\/gthgt-space-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/posts\/8293","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/comments?post=8293"}],"version-history":[{"count":2,"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/posts\/8293\/revisions"}],"predecessor-version":[{"id":8295,"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/posts\/8293\/revisions\/8295"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/media\/8002"}],"wp:attachment":[{"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/media?parent=8293"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/categories?post=8293"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yunrui-controls.com\/ko\/wp-json\/wp\/v2\/tags?post=8293"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}