{"id":7836,"date":"2026-06-21T16:39:58","date_gmt":"2026-06-21T16:39:58","guid":{"rendered":"https:\/\/www.yunrui-controls.com\/?p=7836"},"modified":"2026-06-21T17:53:59","modified_gmt":"2026-06-21T17:53:59","slug":"technical-manual-fisher-627-series-regulator","status":"publish","type":"post","link":"https:\/\/www.yunrui-controls.com\/ja\/technical-manual-fisher-627-series-regulator\/","title":{"rendered":"\u6280\u8853\u30de\u30cb\u30e5\u30a2\u30eb\uff1a\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc627\u30b7\u30ea\u30fc\u30ba\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u306e\u30a8\u30f3\u30b8\u30cb\u30a2\u30ea\u30f3\u30b0\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3001\u9078\u5b9a\u3001\u304a\u3088\u3073\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9"},"content":{"rendered":"<p>\u73fe\u4ee3\u306e\u7523\u696d\u7528\u6d41\u4f53\u5236\u5fa1\u3067\u306f\u3001 <strong>\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc <a href=\"https:\/\/www.yunrui-controls.com\/ja\/products\/fisher-627-series\/\">627 pressure regulator<\/a><\/strong> is one of the most widely used direct-operated gas pressure regulators in industrial and commercial applications. The Fisher 627 pressure regulator is widely utilized for pressure regulation in natural gas distribution, industrial boilers, air compressor systems, and various corrosive media environments. Due to its direct-acting design, this series exhibits exceptional stability under volatile load conditions, making it a cornerstone of industrial gas regulation.<\/p>\n<p>As a core product supplied by YUNRUI, we provide a full range of Fisher 627 pressure regulator stock from DN20 to DN50 and are dedicated to assisting engineers with every detail, from initial selection to field application.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter\" title=\"Fisher 627 Flanged Pressure Regulator - YUNRUI\" src=\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627%E7%B3%BB%E5%88%971-300x225.jpg\" alt=\"Fisher 627 pressure regulator with flanged connections for industrial gas distribution\" width=\"599\" height=\"449\" \/><\/p>\n<h2>1. Fisher 627 Pressure Regulator Structural Analysis: Engineering Logic for Harsh Conditions<\/h2>\n<p>The core of the <strong>Fisher 627 pressure regulator<\/strong> design lies in its precision force-balance system and high material adaptability, allowing it to cover scenarios ranging from standard fuel gas to high-pressure chemical processing.<\/p>\n<h3>Fisher 627 Material and Size Selection<\/h3>\n<ul>\n<li><strong>Ductile Iron Body:<\/strong> Common models of the Fisher 627 pressure regulator include the 627-496, available in DN25 or DN50. Due to its high cost-effectiveness, it is frequently used in city gas regulator stations and standard air systems. Maximum inlet pressure: 1000 psig \/ 69 bar.<\/li>\n<li><strong>Carbon Steel Body (WCC):<\/strong> Designed for high-pressure environments in oil and gas or petrochemical industries, providing superior mechanical strength and pressure-bearing capacity. Maximum inlet pressure: 2000 psig \/ 138 bar (NPT) or 1500 psig \/ 103 bar (flanged).<\/li>\n<li><strong>Stainless Steel Body (CF8M\/316SS):<\/strong> Customized for sour gas (NACE compliant) or chemically corrosive process media, ensuring the valve body remains free from pitting or perforation during long-term operation. Maximum inlet pressure: 2000 psig \/ 138 bar (NPT) or 1440 psig \/ 99.3 bar (flanged).<\/li>\n<\/ul>\n<h3>Fisher 627 Orifice Selection Guide<\/h3>\n<p>\u306e <strong>Fisher 627 pressure regulator<\/strong> series offers orifice sizes ranging from 3\/32\u2033 to 1\/2\u2033. A smaller orifice can withstand higher inlet pressures but provides lower flow capacity (Cv value).<\/p>\n<table>\n<tbody>\n<tr>\n<th>\u30aa\u30ea\u30d5\u30a3\u30b9\u30b5\u30a4\u30ba<\/th>\n<th>Cg (Gas)<\/th>\n<th>Cv (Liquid)<\/th>\n<th>\u30d9\u30b9\u30c8\u30a2\u30d7\u30ea<\/th>\n<\/tr>\n<tr>\n<td>3\/32\u2033 (2.4 mm)<\/td>\n<td>6.9<\/td>\n<td>0.24<\/td>\n<td>Very low flow, precise control<\/td>\n<\/tr>\n<tr>\n<td>1\/8\u2033 (3.2 mm)<\/td>\n<td>12.5<\/td>\n<td>0.43<\/td>\n<td>Low flow pilot systems<\/td>\n<\/tr>\n<tr>\n<td>3\/16\u2033 (4.8 mm)<\/td>\n<td>29<\/td>\n<td>1.01<\/td>\n<td>Small commercial applications<\/td>\n<\/tr>\n<tr>\n<td>1\/4\u2033 (6.4 mm)<\/td>\n<td>50<\/td>\n<td>1.71<\/td>\n<td>Standard commercial\/industrial<\/td>\n<\/tr>\n<tr>\n<td>3\/8\u2033 (9.5 mm)<\/td>\n<td>108<\/td>\n<td>3.42<\/td>\n<td>High flow distribution<\/td>\n<\/tr>\n<tr>\n<td>1\/2\u2033 (13 mm)<\/td>\n<td>190<\/td>\n<td>5.29<\/td>\n<td>Large industrial, city gate stations<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\u9078\u629e\u306e\u30d2\u30f3\u30c8\uff1a<\/strong> It is recommended to set the maximum gas demand at 70%-80% of the valve&#8217;s rated capacity to achieve optimal regulation accuracy and prevent valve plug hunting.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" title=\"Fisher 627 NPT Pressure Regulator - YUNRUI\" src=\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627%E7%B3%BB%E5%88%972-225x300.jpg\" alt=\"Fisher 627 NPT threaded pressure regulator with direct-acting design\" width=\"622\" height=\"829\" \/><\/p>\n<h2>2. Fisher 627 Model Codes and Variants<\/h2>\n<p>Understanding the Fisher 627 pressure regulator suffix codes is vital for precise selection, as these suffixes define the functional boundaries of the valve.<\/p>\n<table>\n<tbody>\n<tr>\n<th>\u30e2\u30c7\u30eb<\/th>\n<th>\u4e3b\u306a\u6280\u8853\u7684\u7279\u5fb4<\/th>\n<th>Pressure Sensing<\/th>\n<th>\u4ee3\u8868\u7684\u306a\u7528\u9014<\/th>\n<\/tr>\n<tr>\n<td><strong>627<\/strong><\/td>\n<td>Standard direct-acting with pitot tube<\/td>\n<td>Internal (pitot tube)<\/td>\n<td>General gas distribution, commercial buildings, industrial boilers<\/td>\n<\/tr>\n<tr>\n<td><strong>627R<\/strong><\/td>\n<td>Internal relief valve + travel stop<\/td>\n<td>Internal + relief<\/td>\n<td>Systems requiring overpressure protection<\/td>\n<\/tr>\n<tr>\n<td><strong>627LR<\/strong><\/td>\n<td>Light-rate internal relief<\/td>\n<td>Internal + light relief<\/td>\n<td>Low-pressure systems needing precise protection<\/td>\n<\/tr>\n<tr>\n<td><strong>627M<\/strong><\/td>\n<td>External sensing capability<\/td>\n<td>External 1\/4 NPT control line<\/td>\n<td>High outlet pressure or remote sensing applications<\/td>\n<\/tr>\n<tr>\n<td><strong>627BM<\/strong><\/td>\n<td>Balanced port + external sensing<\/td>\n<td>External + balanced trim<\/td>\n<td>Varying inlet pressure conditions<\/td>\n<\/tr>\n<tr>\n<td><strong>627MR<\/strong><\/td>\n<td>External sensing + internal relief<\/td>\n<td>External + relief<\/td>\n<td>High-pressure systems needing dual protection<\/td>\n<\/tr>\n<tr>\n<td><strong>627BMR<\/strong><\/td>\n<td>Balanced port + external + relief<\/td>\n<td>External + balanced + relief<\/td>\n<td>Critical applications with varying conditions<\/td>\n<\/tr>\n<tr>\n<td><strong>627H<\/strong><\/td>\n<td>High outlet pressure (up to 500 psig)<\/td>\n<td>Internal with diaphragm limiter<\/td>\n<td>High-pressure outlet applications<\/td>\n<\/tr>\n<tr>\n<td><strong>627HM<\/strong><\/td>\n<td>High pressure + external sensing<\/td>\n<td>External sensing for high outlet<\/td>\n<td>High-pressure systems with remote monitoring<\/td>\n<\/tr>\n<tr>\n<td><strong>627W<\/strong><\/td>\n<td>Liquid service optimization<\/td>\n<td>Internal (optimized for liquids)<\/td>\n<td>Water, hydraulic oil, liquid media<\/td>\n<\/tr>\n<tr>\n<td><strong>627OSX<\/strong><\/td>\n<td>Slam-shut overpressure\/underpressure protection (OPSO\/UPSO\/OPSO+OPSO)<\/td>\n<td>Internal + emergency shut-off<\/td>\n<td>Safety-critical gas distribution systems requiring automatic overpressure or underpressure shutdown<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>3. Fisher 627 Pressure and Temperature Specifications<\/h2>\n<h3>Body Pressure Ratings<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u672c\u4f53\u6750\u8cea<\/th>\n<th>\u63a5\u7d9a\u30bf\u30a4\u30d7<\/th>\n<th>\u6700\u5927\u5165\u53e3\u5727\u529b<\/th>\n<\/tr>\n<tr>\n<td>\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc<\/td>\n<td>NPT<\/td>\n<td>2000 psig \/ 138 bar<\/td>\n<\/tr>\n<tr>\n<td>\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc<\/td>\n<td>Flanged (CL150\/300\/600 RF, PN16\/25\/40)<\/td>\n<td>1440 psig \/ 99.3 bar (CL600)<\/td>\n<\/tr>\n<tr>\n<td>Carbon Steel<\/td>\n<td>NPT<\/td>\n<td>2000 psig \/ 138 bar<\/td>\n<\/tr>\n<tr>\n<td>Carbon Steel<\/td>\n<td>Flanged (CL150\/300\/600 RF, PN16\/25\/40)<\/td>\n<td>1500 psig \/ 103 bar (CL600)<\/td>\n<\/tr>\n<tr>\n<td>Carbon Steel (627OSX)<\/td>\n<td>NPT, SWE, BWE, CL150\/300\/600 RF, PN16\/25\/40 RF<\/td>\n<td>1500 psig \/ 103 bar<\/td>\n<\/tr>\n<tr>\n<td>\u30c0\u30af\u30bf\u30a4\u30eb\u92f3\u9244<\/td>\n<td>NPT<\/td>\n<td>1000 psig \/ 69 bar<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Valve Disk Materials and Shutoff Classification<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u30c7\u30a3\u30b9\u30af\u7d20\u6750<\/th>\n<th>\u6700\u5927\u5165\u53e3\u5727\u529b<\/th>\n<th>\u906e\u65ad\u30af\u30e9\u30b9<\/th>\n<th>\u5fdc\u7528<\/th>\n<\/tr>\n<tr>\n<td>Nitrile (NBR)<\/td>\n<td>1000 psig \/ 69 bar<\/td>\n<td>Bubble Tight<\/td>\n<td>Natural gas, general service<\/td>\n<\/tr>\n<tr>\n<td>Fluorocarbon (FKM)<\/td>\n<td>300 psig \/ 20.7 bar<\/td>\n<td>Bubble Tight<\/td>\n<td>Chemical resistance, corrosive media<\/td>\n<\/tr>\n<tr>\n<td>Nylon (PA)<\/td>\n<td>2000 psig \/ 138 bar<\/td>\n<td>ANSI\/FCI Class IV<\/td>\n<td>High pressure, tight shutoff required<\/td>\n<\/tr>\n<tr>\n<td>NBR (627B Series)<\/td>\n<td>1000 psig \/ 69 bar<\/td>\n<td>FCI Class VIII<\/td>\n<td>Balanced trim applications<\/td>\n<\/tr>\n<tr>\n<td>PA (627B Series)<\/td>\n<td>1500 psig \/ 103 bar<\/td>\n<td>FCI Class IV<\/td>\n<td>Balanced trim, high pressure<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Diaphragm Case Pressure Limits<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u72b6\u614b<\/th>\n<th>\u30a2\u30eb\u30df\u30cb\u30a6\u30e0<\/th>\n<th>\u30c0\u30af\u30bf\u30a4\u30eb\u92f3\u9244<\/th>\n<th>Steel\/Stainless Steel<\/th>\n<\/tr>\n<tr>\n<td>Prevent Atmospheric Leakage<\/td>\n<td>250 psig<\/td>\n<td>250 psig<\/td>\n<td>250 psig (627R: 800 psig)<\/td>\n<\/tr>\n<tr>\n<td>Prevent Case Rupture<\/td>\n<td>375 psig<\/td>\n<td>465 psig<\/td>\n<td>1500 psig<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Note: Maximum diaphragm case overpressure above setpoint ranges from 60-120 psig depending on specific model configuration.<\/em><\/p>\n<h3>Spring Outlet Pressure Ranges<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u6625\u306e\u8272<\/th>\n<th>\u51fa\u53e3\u5727\u529b\u7bc4\u56f2<\/th>\n<th>Available Models<\/th>\n<\/tr>\n<tr>\n<td>\u9ec4\u8272<\/td>\n<td>5 \u2013 20 psig \/ 0.34 \u2013 1.4 bar<\/td>\n<td>Standard models<\/td>\n<\/tr>\n<tr>\n<td>Green<\/td>\n<td>15 \u2013 40 psig \/ 1.0 \u2013 2.8 bar<\/td>\n<td>Standard models<\/td>\n<\/tr>\n<tr>\n<td>Blue<\/td>\n<td>35 \u2013 80 psig \/ 2.4 \u2013 5.5 bar<\/td>\n<td>Standard models<\/td>\n<\/tr>\n<tr>\n<td>Red<\/td>\n<td>70 \u2013 150 psig \/ 4.8 \u2013 10.3 bar<\/td>\n<td>Standard models<\/td>\n<\/tr>\n<tr>\n<td>Blue (heavy)<\/td>\n<td>140 \u2013 250 psig \/ 9.7 \u2013 17.2 bar<\/td>\n<td>627H\/HM only<\/td>\n<\/tr>\n<tr>\n<td>Red (heavy)<\/td>\n<td>240 \u2013 500 psig \/ 16.5 \u2013 34.5 bar<\/td>\n<td>627H\/HM only<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Temperature Limits by Elastomer<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Elastomer<\/th>\n<th>\u6e29\u5ea6\u7bc4\u56f2<\/th>\n<th>\u5fdc\u7528<\/th>\n<\/tr>\n<tr>\n<td>Nitrile (NBR)<\/td>\n<td>-40\u00b0F to 180\u00b0F \/ -40\u00b0C to 82\u00b0C<\/td>\n<td>Natural gas, standard applications<\/td>\n<\/tr>\n<tr>\n<td>Nitrile (NBR) &#8211; 627OSX<\/td>\n<td>-20\u00b0F to 180\u00b0F \/ -29\u00b0C to 82\u00b0C<\/td>\n<td>Slam-shut applications<\/td>\n<\/tr>\n<tr>\n<td>Fluorocarbon (FKM)<\/td>\n<td>0\u00b0F to 180\u00b0F \/ -18\u00b0C to 82\u00b0C<\/td>\n<td>Chemical resistance, corrosive media<\/td>\n<\/tr>\n<tr>\n<td>Nylon (PA) Disk<\/td>\n<td>-40\u00b0F to 180\u00b0F \/ -40\u00b0C to 82\u00b0C<\/td>\n<td>High pressure, Class IV shutoff<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>4. Fisher 627 vs 627R vs 627M vs 627BM Selection Guide<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\u7279\u5fb4<\/th>\n<th>627<\/th>\n<th>627R<\/th>\n<th>627M<\/th>\n<th>627BM<\/th>\n<\/tr>\n<tr>\n<td>Pressure Sensing<\/td>\n<td>Internal (pitot tube)<\/td>\n<td>Internal + relief<\/td>\n<td>External control line<\/td>\n<td>External + balanced port<\/td>\n<\/tr>\n<tr>\n<td>\u904e\u5727\u4fdd\u8b77<\/td>\n<td>None<\/td>\n<td>Internal relief valve<\/td>\n<td>None<\/td>\n<td>None<\/td>\n<\/tr>\n<tr>\n<td>Inlet Pressure Sensitivity<\/td>\n<td>\u9069\u5ea6<\/td>\n<td>\u9069\u5ea6<\/td>\n<td>\u4f4e\u3044<\/td>\n<td>Very low (balanced)<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5927\u51fa\u53e3\u5727\u529b<\/td>\n<td>150 psig<\/td>\n<td>150 psig<\/td>\n<td>2000 psig (body rating)<\/td>\n<td>2000 psig (body rating)<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u9069\u306a\u7528\u9014<\/td>\n<td>Stable inlet conditions<\/td>\n<td>Systems needing relief<\/td>\n<td>High outlet or remote sensing<\/td>\n<td>Varying inlet pressure<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>5. Fisher 627 Field Calibration Guide: Setting Zero and Span<\/h2>\n<p>When calibrating the Fisher 627 pressure regulator, it is essential to strictly follow downstream pressure relief procedures. Never force the compression of the spring in a fully closed state, as this may damage the diaphragm.<\/p>\n<ul>\n<li><strong>Setting Outlet Pressure:<\/strong> This is achieved by rotating the adjustment bolt at the top of the actuator. Rotating clockwise increases the pressure of the internal adjustment spring, thereby raising the outlet pressure setting.<\/li>\n<li><strong>Verifying Spring Range:<\/strong> Every Fisher 627 pressure regulator has a specific spring pressure range (e.g., 5-20 psi or 70-150 psi). Do not attempt to achieve pressures outside the design range by over-compressing the spring, as this leads to spring fatigue or diaphragm damage. If the required setting does not match, contact YUNRUI immediately to exchange for the correct spring assembly.<\/li>\n<\/ul>\n<h2>6. Fisher 627 Troubleshooting: Common Field Issues and Solutions<\/h2>\n<p>During long-term operation, gas quality or environmental factors may cause regulation anomalies in the Fisher 627 pressure regulator. The YUNRUI technical team has summarized the following diagnostic guide:<\/p>\n<table>\n<tbody>\n<tr>\n<th>\u75c7\u72b6<\/th>\n<th>\u6f5c\u5728\u7684\u306a\u539f\u56e0<\/th>\n<th>\u89e3\u6c7a<\/th>\n<\/tr>\n<tr>\n<td>Outlet pressure creep (failure to lock up)<\/td>\n<td>Debris on the orifice or worn valve disk<\/td>\n<td>Clean the orifice or replace the valve disk seal<\/td>\n<\/tr>\n<tr>\n<td>\u4f4e\u6d41\u91cf\u6642\u306e\u5727\u529b\u5909\u52d5<\/td>\n<td>Valve is oversized; orifice too large<\/td>\n<td>Install smaller orifice or select smaller body size<\/td>\n<\/tr>\n<tr>\n<td>Excessive droop at high flow<\/td>\n<td>Undersized valve; insufficient Cv<\/td>\n<td>Replace with larger orifice or body size<\/td>\n<\/tr>\n<tr>\n<td>External leakage from diaphragm case<\/td>\n<td>Diaphragm damage or improper assembly<\/td>\n<td>Replace diaphragm and inspect case for damage<\/td>\n<\/tr>\n<tr>\n<td>Relief valve constantly venting (627R\/LR\/MR\/BMR)<\/td>\n<td>Outlet pressure set too high; relief spring weak<\/td>\n<td>Verify setpoint within spring range; replace relief spring if necessary<\/td>\n<\/tr>\n<tr>\n<td>No response to adjustment bolt rotation<\/td>\n<td>Broken spring; seized linkage; blocked pitot tube<\/td>\n<td>Disassemble and inspect internal components<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" class=\"aligncenter\" title=\"Fisher 627 Internal Components - YUNRUI\" src=\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627%E7%B3%BB%E5%88%973.jpg\" alt=\"Fisher 627 regulator disassembled showing internal components and trim parts\" width=\"743\" height=\"991\" \/><\/p>\n<h2>7. Fisher 627 Maintenance Schedule<\/h2>\n<p>Direct-operated regulators like the Fisher 627 pressure regulator require periodic inspection and maintenance:<\/p>\n<ul>\n<li><strong>Annual Inspection:<\/strong> Check for external leaks, diaphragm condition, and spring integrity.<\/li>\n<li><strong>Trim Wear Check:<\/strong> Monitor outlet pressure stability; increasing droop indicates seat or plug wear.<\/li>\n<li><strong>Filter Maintenance:<\/strong> Clean or replace upstream strainers based on service conditions.<\/li>\n<li><strong>Spring Replacement:<\/strong> If setpoint cannot be maintained, the spring may have taken a set.<\/li>\n<li><strong>Relief Function Test (627R\/LR\/MR\/BMR):<\/strong> Verify internal relief valve opens at specified overpressure.<\/li>\n<\/ul>\n<h2>\u95a2\u9023\u6587\u732e<\/h2>\n<p>Expand your knowledge of pressure regulation and control systems:<\/p>\n<ul>\n<li><a href=\"https:\/\/www.yunrui-controls.com\/ja\/fisher-67cfr-troubleshooting-guide\/\">Fisher 67CFR \u30d5\u30a3\u30eb\u30bf\u30fc\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u30fc\uff1a\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u3001\u4fee\u7406\u3001\u90e8\u54c1\u306b\u95a2\u3059\u308b\u5b8c\u5168\u30ac\u30a4\u30c9<\/a> \u2014 Filter regulator maintenance and repair procedures<\/li>\n<li><a href=\"https:\/\/www.yunrui-controls.com\/ja\/fisher-ezr-pressure-reducing-regulator\/\">\u30d5\u30a3\u30c3\u30b7\u30e3\u30fcEZR\u6e1b\u5727\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u30fc\uff1a\u6280\u8853\u4ed5\u69d8\u3068\u7528\u9014<\/a> \u2014 Pilot-operated regulator for higher accuracy applications<\/li>\n<li><a href=\"https:\/\/www.yunrui-controls.com\/ja\/fisher-valve-selection-guide\/\">\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30d0\u30eb\u30d6\u9078\u5b9a\u30ac\u30a4\u30c9\uff1a\u7523\u696d\u7528\u9014\u5411\u3051\u5b8c\u5168\u6280\u8853\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/a> \u2014 Comprehensive valve selection methodology<\/li>\n<li><a href=\"https:\/\/www.yunrui-controls.com\/ja\/control-valve-accessories-guide\/\">\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u30d0\u30eb\u30d6\u30a2\u30af\u30bb\u30b5\u30ea\u30ac\u30a4\u30c9\uff1a\u30dd\u30b8\u30b7\u30e7\u30ca\u30fc\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u30fc\u306a\u3069<\/a> \u2014 Understanding the complete control valve package<\/li>\n<li><a href=\"https:\/\/www.yunrui-controls.com\/ja\/fisher-dvc6200-vs-siemens-ps2\/\">Fisher DVC6200 vs Siemens PS2\uff1a\u30c7\u30b8\u30bf\u30eb\u30d0\u30eb\u30d6\u30dd\u30b8\u30b7\u30e7\u30ca\u30fc\u6bd4\u8f03\u30ac\u30a4\u30c9<\/a> \u2014 Smart positioner technology comparison<\/li>\n<\/ul>\n<h2>\u898b\u7a4d\u3082\u308a\u3092\u4f9d\u983c\u3059\u308b<\/h2>\n<p>For pricing, availability, and technical assistance with <strong><a href=\"https:\/\/www.yunrui-controls.com\/ja\/products\/fisher-627-series\/\">\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc627<\/a> pressure regulators<\/strong>, \u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30a8\u30f3\u30b8\u30cb\u30a2\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><strong>\u30e1\u30fc\u30eb\u30a2\u30c9\u30ec\u30b9:<\/strong> <a href=\"mailto:sales@yunrui-controls.com\">sales@yunrui-controls.com<\/a><br \/>\n<strong>WhatsApp:<\/strong> <a href=\"https:\/\/wa.me\/8618710784030\">18710784030<\/a><\/p>\n<p>We supply genuine Fisher regulators with full factory support, fast global delivery, and competitive pricing for volume orders.<\/p>","protected":false},"excerpt":{"rendered":"<p>In modern industrial fluid control, the Fisher 627 pressure regulator is one of the most widely used direct-operated gas pressure regulators in industrial and commercial applications. The Fisher 627 pressure regulator is widely utilized for pressure regulation in natural gas distribution, industrial boilers, air compressor systems, and various corrosive media environments. Due to its direct-acting [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7837,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[384,1],"tags":[],"class_list":["post-7836","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-blogs"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.8 (Yoast SEO v26.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Fisher 627 Pressure Regulator | Selection Guide &amp; Model Codes<\/title>\n<meta name=\"description\" content=\"Complete Fisher 627 pressure regulator manual. 11 models, 2000 psig rating, Cv tables, troubleshooting. Genuine stock - YUNRUI\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.yunrui-controls.com\/ja\/technical-manual-fisher-627-series-regulator\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Technical Manual: Fisher 627 Series Regulator Engineering Applications, Selection, and Maintenance\" \/>\n<meta property=\"og:description\" content=\"Complete Fisher 627 pressure regulator manual. 11 models, 2000 psig rating, Cv tables, troubleshooting. Genuine stock - YUNRUI\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.yunrui-controls.com\/ja\/technical-manual-fisher-627-series-regulator\/\" \/>\n<meta property=\"og:site_name\" content=\"Fisher, E+H &amp; Rosemount Supplier from China | 100% Original | YUNRUI\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-21T16:39:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-21T17:53:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627\u7cfb\u5217.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1440\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"sales@yunrui-controls.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"sales@yunrui-controls.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"10\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/\"},\"author\":{\"name\":\"sales@yunrui-controls.com\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/b9b385704b61e72ea9254fc3b56001af\"},\"headline\":\"Technical Manual: Fisher 627 Series Regulator Engineering Applications, Selection, and Maintenance\",\"datePublished\":\"2026-06-21T16:39:58+00:00\",\"dateModified\":\"2026-06-21T17:53:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/\"},\"wordCount\":1413,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627\u7cfb\u5217.jpg\",\"articleSection\":[\"News\",\"Blogs\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/\",\"url\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/\",\"name\":\"Fisher 627 Pressure Regulator | Selection Guide & Model Codes\",\"isPartOf\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627\u7cfb\u5217.jpg\",\"datePublished\":\"2026-06-21T16:39:58+00:00\",\"dateModified\":\"2026-06-21T17:53:59+00:00\",\"description\":\"Complete Fisher 627 pressure regulator manual. 11 models, 2000 psig rating, Cv tables, troubleshooting. Genuine stock - YUNRUI\",\"breadcrumb\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#primaryimage\",\"url\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627\u7cfb\u5217.jpg\",\"contentUrl\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627\u7cfb\u5217.jpg\",\"width\":1080,\"height\":1440,\"caption\":\"Original Fisher 627 Series Regulator from Chinese supplier Yunrui.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.yunrui-controls.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Technical Manual: Fisher 627 Series Regulator Engineering Applications, Selection, and Maintenance\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#website\",\"url\":\"https:\/\/www.yunrui-controls.com\/\",\"name\":\"Process Instrument & Valve Supplier from China | YUNRUI\",\"description\":\"YUNRUI is your trusted authorized distributor and stockist in China for original Fisher valves, E+H, and Rosemount instruments. Fast Middle East delivery. Get a quote!\",\"publisher\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/#organization\"},\"alternateName\":\"YRCONTROLS\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.yunrui-controls.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#organization\",\"name\":\"YUNRUI\",\"alternateName\":\"YUNRUI TRADING\",\"url\":\"https:\/\/www.yunrui-controls.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/03\/original-yunrui-logo-from-china-supplier-yunrui.png\",\"contentUrl\":\"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/03\/original-yunrui-logo-from-china-supplier-yunrui.png\",\"width\":512,\"height\":512,\"caption\":\"YUNRUI\"},\"image\":{\"@id\":\"https:\/\/www.yunrui-controls.com\/#\/schema\/logo\/image\/\"},\"telephone\":\"8618710784030\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/b9b385704b61e72ea9254fc3b56001af\",\"name\":\"sales@yunrui-controls.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/42e338d7dd3c1419e51612bcfd01acd3eca969f2e93b9e49b772042eceaf1030?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/42e338d7dd3c1419e51612bcfd01acd3eca969f2e93b9e49b772042eceaf1030?s=96&d=mm&r=g\",\"caption\":\"sales@yunrui-controls.com\"},\"sameAs\":[\"https:\/\/www.yunrui-controls.com\"],\"url\":\"https:\/\/www.yunrui-controls.com\/ja\/author\/gthgt-space-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Fisher 627 Pressure Regulator | Selection Guide & Model Codes","description":"Complete Fisher 627 pressure regulator manual. 11 models, 2000 psig rating, Cv tables, troubleshooting. Genuine stock - YUNRUI","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.yunrui-controls.com\/ja\/technical-manual-fisher-627-series-regulator\/","og_locale":"ja_JP","og_type":"article","og_title":"Technical Manual: Fisher 627 Series Regulator Engineering Applications, Selection, and Maintenance","og_description":"Complete Fisher 627 pressure regulator manual. 11 models, 2000 psig rating, Cv tables, troubleshooting. Genuine stock - YUNRUI","og_url":"https:\/\/www.yunrui-controls.com\/ja\/technical-manual-fisher-627-series-regulator\/","og_site_name":"Fisher, E+H &amp; Rosemount Supplier from China | 100% Original | YUNRUI","article_published_time":"2026-06-21T16:39:58+00:00","article_modified_time":"2026-06-21T17:53:59+00:00","og_image":[{"width":1080,"height":1440,"url":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627\u7cfb\u5217.jpg","type":"image\/jpeg"}],"author":"sales@yunrui-controls.com","twitter_card":"summary_large_image","twitter_misc":{"\u57f7\u7b46\u8005":"sales@yunrui-controls.com","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"10\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#article","isPartOf":{"@id":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/"},"author":{"name":"sales@yunrui-controls.com","@id":"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/b9b385704b61e72ea9254fc3b56001af"},"headline":"Technical Manual: Fisher 627 Series Regulator Engineering Applications, Selection, and Maintenance","datePublished":"2026-06-21T16:39:58+00:00","dateModified":"2026-06-21T17:53:59+00:00","mainEntityOfPage":{"@id":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/"},"wordCount":1413,"commentCount":0,"publisher":{"@id":"https:\/\/www.yunrui-controls.com\/#organization"},"image":{"@id":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#primaryimage"},"thumbnailUrl":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627\u7cfb\u5217.jpg","articleSection":["News","Blogs"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/","url":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/","name":"Fisher 627 Pressure Regulator | Selection Guide & Model Codes","isPartOf":{"@id":"https:\/\/www.yunrui-controls.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#primaryimage"},"image":{"@id":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#primaryimage"},"thumbnailUrl":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627\u7cfb\u5217.jpg","datePublished":"2026-06-21T16:39:58+00:00","dateModified":"2026-06-21T17:53:59+00:00","description":"Complete Fisher 627 pressure regulator manual. 11 models, 2000 psig rating, Cv tables, troubleshooting. Genuine stock - YUNRUI","breadcrumb":{"@id":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#primaryimage","url":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627\u7cfb\u5217.jpg","contentUrl":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/04\/627\u7cfb\u5217.jpg","width":1080,"height":1440,"caption":"Original Fisher 627 Series Regulator from Chinese supplier Yunrui."},{"@type":"BreadcrumbList","@id":"https:\/\/www.yunrui-controls.com\/technical-manual-fisher-627-series-regulator\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.yunrui-controls.com\/"},{"@type":"ListItem","position":2,"name":"Technical Manual: Fisher 627 Series Regulator Engineering Applications, Selection, and Maintenance"}]},{"@type":"WebSite","@id":"https:\/\/www.yunrui-controls.com\/#website","url":"https:\/\/www.yunrui-controls.com\/","name":"\u4e2d\u56fd\u306e\u30d7\u30ed\u30bb\u30b9\u8a08\u6e2c\u6a5f\u5668\u30fb\u30d0\u30eb\u30d6\u30b5\u30d7\u30e9\u30a4\u30e4\u30fc | YUNRUI","description":"YUNRUI\u306f\u3001\u4e2d\u56fd\u306b\u304a\u3051\u308bFisher\u7d14\u6b63\u30d0\u30eb\u30d6\u3001E+H\u3001Rosemount\u88fd\u8a08\u6e2c\u6a5f\u5668\u306e\u4fe1\u983c\u3067\u304d\u308b\u6b63\u898f\u4ee3\u7406\u5e97\u304a\u3088\u3073\u5728\u5eab\u8ca9\u58f2\u5e97\u3067\u3059\u3002\u4e2d\u6771\u3078\u306e\u8fc5\u901f\u306a\u914d\u9001\u3082\u627f\u308a\u307e\u3059\u3002\u304a\u898b\u7a4d\u3082\u308a\u3092\u3054\u5e0c\u671b\u306e\u5834\u5408\u306f\u3001\u304a\u6c17\u8efd\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002","publisher":{"@id":"https:\/\/www.yunrui-controls.com\/#organization"},"alternateName":"YRCONTROLS","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.yunrui-controls.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Organization","@id":"https:\/\/www.yunrui-controls.com\/#organization","name":"\u30e6\u30f3\u30eb\u30a4","alternateName":"YUNRUI TRADING","url":"https:\/\/www.yunrui-controls.com\/","logo":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.yunrui-controls.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/03\/original-yunrui-logo-from-china-supplier-yunrui.png","contentUrl":"https:\/\/www.yunrui-controls.com\/wp-content\/uploads\/2026\/03\/original-yunrui-logo-from-china-supplier-yunrui.png","width":512,"height":512,"caption":"YUNRUI"},"image":{"@id":"https:\/\/www.yunrui-controls.com\/#\/schema\/logo\/image\/"},"telephone":"8618710784030"},{"@type":"Person","@id":"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/b9b385704b61e72ea9254fc3b56001af","name":"sales@yunrui-controls.com","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.yunrui-controls.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/42e338d7dd3c1419e51612bcfd01acd3eca969f2e93b9e49b772042eceaf1030?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/42e338d7dd3c1419e51612bcfd01acd3eca969f2e93b9e49b772042eceaf1030?s=96&d=mm&r=g","caption":"sales@yunrui-controls.com"},"sameAs":["https:\/\/www.yunrui-controls.com"],"url":"https:\/\/www.yunrui-controls.com\/ja\/author\/gthgt-space-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/posts\/7836","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/comments?post=7836"}],"version-history":[{"count":10,"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/posts\/7836\/revisions"}],"predecessor-version":[{"id":8499,"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/posts\/7836\/revisions\/8499"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/media\/7837"}],"wp:attachment":[{"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/media?parent=7836"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/categories?post=7836"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yunrui-controls.com\/ja\/wp-json\/wp\/v2\/tags?post=7836"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}